References - Pressure Control Blower
ETFE-Volume: 9,800 m³
Air cushion: 1 piece
Pressure: 400 Pa
2 x DG-100 T - frequency converter with SAS
ETFE-Volume: 425 m²
Air cushions: 36 pieces, 4-layers
Pressure: 150-300 Pa
movable cushion layer
1 x DG-65 T - frequency converter with SAS
Banking Academy
ETFE-Volume: 600 m³
Pressure: 250 Pa
1 x DG-65 T with frequency converter
ETFE-Volume: 253 / 118 m³
Air cushions: 11 / 9 pieces
Pressure: 200 m³
2 x DG-500 T
ETFE-Volume: 1,375 m³
Air cushions: 69 pieces
Pressure: 300 m³
1 x DG-65 T with frequency converter
ETFE-Volume: 2,500 m³
Air cushion: 1 piece
Pressure: 400 Pa
1 x DG-100 T with frequency converter
Shopping Mall
ETFE-Volume: 850 - 3,750 m³
Air cushions: 4 pieces, 4-layers
3 x DG-100 T with frequency converter
1 x DG-65 T with frequency converter
Roof
ETFE-Volume: approx. 180 m³
Air cushions: 12 pieces
Pressure: 300 Pa
1 x DG-65 T
Facade
ETFE-Volume: approx. 1,000 m³
Air cushions: 27 pieces
Pressure: 300 Pa
1 x DG-65 T with frequency converter
ETFE-Volume: 45 m³
Air cushions: 1 piece
Pressure: 250 - 500 Pa
1 x DG-500 T
ETFE-Volume: 2,000 m³
Air cushions: 83 pieces
Pressure: up to 600 Pa
2 x DG-100 T with frequency converter
ETFE-Volume: 618 m³
Air cushions: 60 pieces
Pressure: up to 750 Pa
1 x DG-65 T with frequency converter
1 x DG-500 T (lying)
ETFE-Volume: 200 m³
Air cushions: 30 pieces
Pressure: up to 400 Pa
1 x DG-65 T
ETFE-Volume: 700 m³
Air cushions: 100 pieces
Pressure: up to 350 Pa
1 x DG-65 T with frequency converter
ETFE-Volume: 1,470 m³
Air cushions: 20 pieces
Pressure: up to 300 Pa
2 x DG-65 T
3 x Corner Dome
ETFE-Volume: 680 m³ / 680 m³ / 500 m³
Air cushions: 112 / 112 / 112 pieces
Pressure: up to 800 Pa
3 x DG - 65 T in 110 V / 60 Hz Version
Europe's largest indoor water park
Air cushion roof: ø 72 m
ETFE-Area: 4.000 m²
Pressure: up to 600 Pa
2 x DG-100 T
ETFE-Area: 650 m²
Air cushions: 45 pieces
Pressure: up to 250 Pa
1 x DG-65 T
ETFE-Area: 360 m²
Air cushions: 22 pieces
Pressure: up to 300 Pa
1 x DG-65 T
ETFE-Area: 550 m²
Air cushions: 122 pieces
Pressure: up to 800 Pa
1 x DG-65 T
1 x DG-65 T with movable center position
ETFE-Volume: 400 - 1.770 m³
Pressure: up to 800 Pa
5 x DG-65 T
3 x DG-100 T
Air output: up to 500 m³/h
Pressure: up to 300 Pa
6 x DG-500 ex
Air output: up to 500 m³/h
Pressure: up to 300 Pa
10 x DG-500 ex
12 pressure control units with dryer
Blower: 0 - 2,000 m³/h
Pressure: 0 - 600 pa
Pressure control unit with dryer
Blower: 0 - 1,000 m³/h
Pressure: 0 - 600 pa
Pressure control unit with dryer
Blower: 0 - 1,000 m³/h
Pressure: 0 - 900 pa
Pressure control unit with dryer
Blower: 0 - 150 m³/h
Pressure: 0 - 500 pa
4 pressure control units with dryer
Blower: 0 - 1,000 m³/h
Pressure: 300 / 800 pa
Pressure control unit with dryer
Blower: 0 - 500 m³/h
Pressure: 0 - 800 pa
Pressure control unit with dryer
Blower: 0 - 150 m³/h
Pressure: 0 - 500 pa
2 pressure control units with dryer
Blower: 0 - 3,000 m³/h
Pressure: 0 - 1,000 pa
Pressure control unit combination with dryer
Consisting of:
Blower for the upper cushion halfs
Blower for the bottom cushion halfs
Exhaust fan for the bottom cushion halfs
Blower: 0 - 500 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 0 - 100 m³/h
Pressure: 0 - 800 pa
Pressure control unit with dryer
Blower: 0 - 100 m³/h
Pressure: 0 - 1,000 pa
5 x pressure control units with dryer
Blower: 0 - 100 m³/h
Pressure: 0 - 500 m³/h
Pressure control unit with dryer
Blower: 900 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 300 m³/h
Pressure: Up to 700 pa
Pressure control unit with dryer
Cushion of 3 layers with movable medial layer
Blower: 615 m³/h
Pressure: Up to 550 pa
Pressure control unit with dryer
Pressure control unit with dryer
Pressure control unit with dryer
Pressure control unit with dryer
Blower: 600 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 600 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 600 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 1,250 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 600 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 1,000 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 1,600 m³/h
Pressure: 0 - 500 pa
Pressure control unit with dryer
Blower: 300 m³/h
Pressure: 0 - 650 pa
Pressure control unit with dryer
Blower: 300 m³/h
Pressure: 0 - 600 pa
Pressure control unit with dryer
Blower: 1,100 m³/h
Pressure: 0 - 600 pa